EPDM Roofing Calculator
Raised Kerb Trim Internal Corners of a rubber roof install

RAISED KERB INTERNAL CORNER

Training hub – all your questions answered!

For the best results, please follow the instructions below.
If you still have questions please feel free to contact us using the form here…

STEP 1

Create an effective corner (ready for Raised Kerb Trim Internal Corners to be fitted) by butt-joining two lengths of Raised Kerb Trim where they meet at an internal right angle.

Make sure to leave a 4mm expansion gap.

Raised Kerb Trim Internal Corners - EPDM roof
Raised Kerb Trim Internal Corners - EPDM roof

STEP 2

If necessary, carefully remove any excess foam seal.

STEP 3

Apply super glue to ONE inside edge of the Raised Kerb Trim Internal Corner component.

(Only one side is superglued to allow for any expansion of the joined lengths of Raised Kerb Trim.)

How to fix Raised Kerb Trim Internal Corners
Apply uPVC superglue activator to the Raised Kerb Trim corner area.

STEP 4

Apply uPVC superglue activator to the Raised Kerb Trim corner area where the superglued inside edge of the Internal Corner component is to be affixed.

STEP 5

Firmly press the Internal Corner component down and into the Raised Kerb Trim butt-joined corner and hold in place until adhesion is solid.

Firmly press the Internal Corner component down